Advanced Search

1700 Series GASTIGHT Syringes

By Hamilton
1700 Series GASTIGHT Syringes

10 µL - 500 µL

  • Cemented needles (N, LTN), removable needles (RN), luer tip (LT), PTFE luer lock (TLL), or PTFE luer lock w/ slots (TLL w/ slots)
  • Precision-machined PTFE PTFE-tipped plungers
  • Replaceable plungers
  • For use with gases and liquids
  • All syringes are autoclavable when disassembled except for the cemented needle (N, LTN) syringes and SampleLock syringes

TLL (PTFE® Luer Lock) w/o slots

Needle not included.

             
Cat.No. Name Capac. Gauge EA    
9-80920 Model 1705 50µL 22s No Price  
9-81020 Model 1710 100 22s No Price  
9-81120 Model 1725 250 22s No Price  
9-81220 Model 1750 500 22s No Price  

TLL (PTFE® Luer Lock) w/ slots

Needle not included.

                 
Cat.No. Name Capac. Gauge O.D. I.D. EA    
9-80927 TLL Syringe (w slots), Model 1705 50µL 22s 0.305 0.041 No Price  
9-81027 TLL Syringe (w slots), Model 1710 100 22s 0.305 0.057 No Price  
9-81127 TLL Syringe (w slots), Model 1725 250 22s 0.305 0.091 No Price  
9-81227 TLL Syringe (w slots), Model 1750 500 22s 0.305 0.128 No Price  

LT (Luer Tip)

Needle not included.

             
Cat.No. Name Capac. Gauge EA    
9-80001 Model 1701 10µL 26s No Price  
9-80201 Model 1702 25 22s No Price  
9-80901 Model 1705 50 22s No Price  
9-81001 Model 1710 100 22s No Price  
9-81101 Model 1725 250 22s No Price  
9-81201 Model 1750 500 22s No Price  

LTN (Cemented Needle)

                 
Cat.No. Name Capac. Gauge O.D. I.D. EA    
9-81217 LTN (Cemented Needle) Syringe, Model 1750 500µL 22 0.305" 0.128" No Price  

LTSN (Cemented Needle)

Specify needle gauge, length and point style at time of order.

                 
Cat.No. Name Capac. Gauge O.D. I.D. EA    
9-81214 LTSN (Cemented Needle) Syringe, Model 1750 500µL 22 0.305" 0.128" No Price  

N (Cemented Needle)

For point styles 3 or 5, please contact Krackeler Scientific Customer Service for ordering information.

             
Cat.No. Name Capac. Gauge/Length/Point Style   EA    
9-80000 Model 1701 10µL 26s/2"/2 No Price  
9-80200 Model 1702 25 22s/2"/2 No Price  
9-80900 Model 1705 50 22s/2"/2 No Price  
9-81000 Model 1710 100 22s/2"/2 No Price  
9-81100 Model 1725 250 22s/2"/2 No Price  

SN (Cemented Needle)

Specify needle gauge, length and point style at time of order.

                 
Cat.No. Name Capac. Gauge O.D. I.D. EA    
9-80008 SN (Cemented Needle) Syringe, Model 1701 10µL 26s 0.260" 0.018" No Price  
9-80208 SN (Cemented Needle) Syringe, Model 1702 25 22s 0.305 0.029 No Price  
9-80908 SN (Cemented Needle) Syringe, Model 1705 50 22s 0.305 0.041 No Price  
9-81008 SN (Cemented Needle) Syringe, Model 1710 100 22s 0.305 0.057 No Price  
9-81108 SN (Cemented Needle) Syringe, Model 1725 250 22s 0.305 0.091 No Price  

RN (Removable Needle) Point Style 2

For point style #3 please call our customer service for ordering information.

               
Cat.No. Name Capac. Point Style Gauge/Length/Point Style   EA    
9-80030 Model 1701 10µL 2 26s/2"/2 No Price  
9-80230 Model 1702 25 2 22s/2"/2 No Price  
9-80930 Model 1705 50 2 22s/2"/2 No Price  
9-81030 Model 1710 100 2 22s/2"/2 No Price  
9-81130 Model 1725 250 2 22s/2"/2 No Price  
9-81230 Model 1750 500 2 22s/2"/2 No Price  

RN (Removable Needle) Point Style 3

                   
Cat.No. Name Capac. Point Style Gauge/Length/Point Style   O.D. I.D. EA    
9-80065 RN (Removable Needle) Point Style 3 Syringe, Model 1701 10µL 3 26s/2"/3 0.260" 0.018 No Price  
9-80265 RN (Removable Needle) Point Style 3 Syringe, Model 1702 25 3 22s/2"/3 0.305 0.029 No Price  
9-80965 RN (Removable Needle) Point Style 3 Syringe, Model 1705 50 3 22s/2"/3 0.305 0.041 No Price  
9-81065 RN (Removable Needle) Point Style 3 Syringe, Model 1710 100 3 22s/2"/3 0.305 0.057 No Price  
9-81165 RN (Removable Needle) Point Style 3 Syringe, Model 1725 250 3 22s/2"/3 0.305 0.091 No Price  
9-81265 RN (Removable Needle) Point Style 3 Syringe, Model 1750 500 3 22s/2"/3 0.305 0.128 No Price  

RN (Removable Needle) Syringe

Needle not included.

                 
Cat.No. Name Capac. Gauge O.D. I.D. EA    
9-7653-01 RN (Removable Needle) Syringe, Model 1701 10µL 26s 0.260" 0.018" No Price  
9-7654-01 RN (Removable Needle) Syringe, Model 1702 25 22s 0.305 0.029 No Price  
9-7655-01 RN (Removable Needle) Syringe, Model 1705 50 22s 0.305 0.041 No Price  
9-7656-01 RN (Removable Needle) Syringe, Model 1710 100 22s 0.305 0.057 No Price  
9-7657-01 RN (Removable Needle) Syringe, Model 1725 250 22s 0.305 0.091 No Price  
9-7658-01 RN (Removable Needle) Syringe, Model 1750 500 22s 0.305 0.128 No Price  

SampleLock Syringe

             
Cat.No. Name Capac. Gauge/Length/Point Style   EA    
9-80956 Model 1705 50µL 22s/2"/2 No Price  
9-81056 Model 1710 100 22s/2"/2 No Price  
9-81156 Model 1725 250 22s/2"/2 No Price  
9-81256 Model 1750 500 22s/2"/2 No Price  

The following items have been added to your cart:

Choose a favorite list for this item:

Catalog Number Description Price
$

Returns/Order support

Please fill out the form below if you want to request order support from Krackeler Scientific.


Quick Order

* Required


New Year Price Updates

We are currently working diligently to update our website pricing information for the New Year. If you place an order, you will be acknowledged with any corrected pricing. If you'd like the most current information sooner, please don't hesitate to drop us an email or give us a call and we'd be happy to assist. Thank you for your patience while we are updating.

800-334-7725
ben@krackeler.com


Play Video

To Request a Quote

  1. Search or Browse for items and add to them to your Shopping Cart.
  2. Click the "Request Quote" button at the bottom of the Shopping Cart page.
  3. Fill out required fields.
  4. Optionally you can convert to standard checkout mode by choosing a payment type.
  5. Click "Request Quote" at the bottom of the page.

You will be contacted with a quote.

To Order From a Quote

  1. Register and login to the website.
  2. Receive a quote from your sales representative or customer service.
  3. Have your copy of the quote in hand.
  4. Visit our quote module to search for your quote.
Back to Top